Table of Contents
citron - Citron Infrared Touch Driver (CiTouch)
Section
"InputDevice"""
Identifier idevname
Driver "citron"""
Option Device devpath
...
EndSection
citron is a Xorg input driver for Citron Infrared
Touch devices.
The citron driver acts as a pointer input device, and may
be used as the X server's core pointer. It is connected via a "RS232" with
the host.
At the moment the following touches are supported.
They are also available as ZPress touches.
IRT6I5-V2.x 6.5 inch Infrared Touch
IRT10I4-V4.x 10.4 inch Infrared Touch
IRT12I1-V2.x 12.1 inch Infrared Touch
IRT15I1-V1.x 15.1 inch Infrared Touch
Please refer to xorg.conf(5x)
for general configuration
details and for options that can be used with all input drivers. This section
only covers configuration details specific to this driver. For better understanding
please read also the CTS and various IRT manuals which are available in
"pdf" format from Citron web page www.citron.de or directly from Citron.
The following driver Options are supported:
- Option Device devpath
- Specify
the device path for the citron touch. Valid devices are:
/dev/ttyS0, /dev/ttyS1,
.... This option is mandatory.
It's important to specify the right device Note:
com1 -> /dev/ttyS0, com2 -> /dev/ttyS1 ....
- Option ScreenNumber screennumber
- sets
the screennumber for the citron InputDevice.
Default: ScreenNumber: "0"
- Option MinX, MinY value
- These are the minimum X and Y values for the
citron input device.
Note: MinX, MinY must be less than MaxX, MaxY.
Range:
"0" - "65535"
Default: MinX: "0" MinY: "0"
- Option MaxX, MaxY value
- These
are the maximum X and Y values for the citron input device.
Note: MaxX,
MaxY must be greater than MinX, MinY.
Range: "0" - "65535"
Default: MaxX:
"65535" MaxY: "65535"
- Option ButtonNumber value
- This value is responsible
for the button number that is returned within the xf86PostButton event
message
Range: "0" - "255"
Default: "1"
- Option ButtonThreshold value
- This value is responsible for the button threshold. It changes the pressure
sensitivity of the touch. A higher number corresponds to a higher pressure.
Note: This feature is only available with pressure sensitive hardware.
Range:
"0" - "255"
Default: "20"
- Sleep-Mode
- If the IRT is in Doze-Mode and Touch
Zone is not interrupted for another certain span of time, the so-called
Sleep-Mode is activated. The Sleep-Mode decreases the scan rate of the beams
even further than the Doze-Mode does (see below). This way the life expectancy
of the beams is prolonged and the power consumption of the IRT is reduced.
As soon as an interruption of the Touch Zone is detected, the Sleep-Mode
is deactivated and the Touch Zone will again be scanned with the maximum
speed. With the Sleep-Mode activated, depending on the set scan rate the
IRT's response time can be considerably longer as in normal operation. If,
for example, a scan rate of 500 ms / scan is set, it may last up to a
half of a second until the IRT detects the interruption and deactivates
the Sleep-Mode.
- Option SleepMode mode
- This value is responsible for the
sleep-mode of the touch.
Determines the behaviour of the Sleep-Mode.
0x00
No message at either activation or deactivation
0x01 Message at activation
0x02 Message at deactivation
0x03 Message at activation and deactivation
0x10 GP_OUT output set according to the Sleep-Mode status
Values: "0"
"1" "2" "3" "16"
Default: "0"
- Option SleepTime time
- This value is responsible
for the sleep-time of the touch. It is the activation time in seconds ("0"
= immediately activated, "65535" = always deactivated).
Range: "0" - "65535"
[s]
Default: "65535" => deactivated
- Option SleepScan scan
- This value is
responsible for the scan-time of the touch. This is the time interval between
two scan operations while in Sleep-Mode. The time interval is set in steps
of milliseconds.
Range: "0" - "65535" [ms]
Default: "500"
- Option PWMAdjSrc
value
- Option PWMAdjDst value
- These parameters are used to adjust the brightness
of different backlight inverters. At the moment 2 backlight inverters are
used: 0=TDK 1=AC. If you want a AC backlight inverter to behave like
an AC type you have to set PWMAdjSrc to 0 (TDK) and PWMAdjDst to 1 (AC).
Range: "0" - "1"
Default: "-1" (no adjustment)
- Option PWMActive value
- This value determines the mark-to-space ratio of the PWM output while in
normal operation (sleep-mode not active). Higher values result in longer
pulse widths. This output signal can be used in conjunction with the Citron
AWBI to do backlight-dimming via the touch.
Range: "0" - "255"
Default:
"255" (max. brightness)
- Option PWMSleep value
- This value determines the
mark-to-space ratio of the PWM output while in sleep-mode (-> SleepMode, SleepScan,
SleepTime ) operation (sleep-mode active). Higher values result in longer
pulse widths.
Range: "0" - "255"
Default: "255" (max. brightness)
- Option
PWMFreq value
- This value determines the PWM frequency in Hertz
Range:
"39" - "9803"
Default: "9803" (max. frequency)
- Option ClickMode mode
- With
mode one can select between 5 ClickModes
"1"" = ClickMode Enter
With
this mode every interruption of the infrared beams will activate a ButtonPress
event and after the interruption a ButtonRelease event will be sent.
"2""
= ClickMode Dual
With this mode every interruption will sent a Proximity
event and every second interruption a ButtonPress event. With the release
of the interruption (while one interruption is still active) a ButtonRelease
event will be sent.
"3"" = ClickMode Dual Exit
With this mode every interruption
will sent a ProximityIn event and every second interruption a ButtonPress
event. With the release of the interruption (while one interruption is still
active) no ButtonRelease event will be sent. Only if all interruptions are
released a ButtonRelease followed by a ProximityOut event will be sent.
"4"" = ClickMode ZPress
With this mode every interruption will sent a
ProximityIn event. Only if a certain pressure is exceeded a ButtonPress
event will occur. If the pressure falls below a certain limit a ButtonRelease
event will be sent. After also the interruption is released a ProximityOut
event is generated.
"5"" = ClickMode ZPress Exit
This mode is similat
to "Clickmode Dual Exit". The first interruption of the beams will sent
a ProximityIn event. Only if a certain pressure is exceeded a ButtonPress
event will occur. If the pressure falls below a certain limit no ButtonRelease
event will be sent. After the interruption is also released a ButtonRelease
followed by a ProximityOut event is generated.
Range: "1" - "5"
Default:
"1" (ClickMode Enter)
- Option Origin value
- This value sets the coordinates
origin to one of the four corners of the screen. The following values are
accepted: "0" TOPLEFT: Origin set to the left-hand side top corner. "1" TOPRIGHT:
Origin set to the right-hand side top corner. "2" BOTTOMRIGHT: Origin set
to the right-hand side bottom corner. "3" BOTTOMLEFT: Origin set to the left-hand
side bottom corner.
Range: "0" - "3"
Default: "0" (TOPLEFT)
- Doze-Mode
- If
for a certain span of time the Touch Zone is not interrupted, the so-called
Doze-Mode is automatically activated. The activated Doze-Mode slightly decreases
the scan rate of the beams. This way the power consumption of the IRT is
reduced. As soon as an interruption of the Touch Zone is detected, the
Doze-Mode is deactivated and the Touch Zone will again be scanned with
the maximum speed.
- Option DozeMode mode
- This value is responsible for the
doze-mode of the touch.
Determines the behaviour of the Doze-Mode.
0x00 No
message at either activation or deactivation
0x01 Message at activation
0x02 Message at deactivation
0x03 Message at activation and deactivation
0x10 GP_OUT output set according to the Doze-Mode status
If the GP_OUT
output is already controlled by the Sleep-Mode it is no longer available
as an output port anymore.
Values: "0" "1" "2" "3" "16"
Default: "0"
- Option DozeTime time
- This value is responsible for the doze-time of the
touch. It is the activation time in seconds ("0" = immediately activated,
"65535" = always deactivated).
Range: "0" - "65535" [s]
Default: "65535"
=> deactivated
- Option DozeScan scan
- This value is responsible for the
scan-time of the touch. This is the time interval between two scan operations
while in Doze-Mode. The time interval is set in steps of milliseconds.
Range:
"0" - "65535" [ms]
Default: "500"
- Option DeltaX value
- This value determines
a virtual area at the left and right side of the current cursor position
where the cursor didn't move. Within this area no "MotionNotify" event will
be sent.
Range: "0" - "255"
Default: "0" (no deltaX)
- Option DeltaY value
- This value determines a virtual area at the top and bottom of the current
cursor position where the cursor didn't move. Within this area no "MotionNotify"
event will be sent.
Range: "0" - "255"
Default: "0" (no deltaY)
- Option
Beep value
- This value determines if a "ButtonPress" and/or a "ButtonRelease"
event should sound the buzzer. "0" deactivates the buzzer while every other
value will activate it.
Range: "0" - "1"
Default: "0" (deactivated)
- Option
PressVol value
- This value determines the volume of the buzzer (0-100%) when
a "ButtonPress" event is sent.
Range: "0" - "100"
Default: "100"
- Option
PressPitch value
- This value determines the pitch of the tone when a "ButtonPress"
event is sent.
Range: "0" - "3000"
Default: "880"
- Option PressDur value
- This value determines the duration of the tone in ms when a "ButtonPress"
event is sent.
Range: "0" - "255"
Default: "15"
- Option ReleaseVol value
- This value determines the volume of the buzzer (0-100%) when a "ButtonRelease"
event is sent.
Range: "0" - "100"
Default: "100"
- Option ReleasePitch
value
- This value determines the pitch of the tone when when a "ButtonRelease"
event is sent.
Range: "0" - "3000"
Default: "1200"
- Option ReleseDur
value
- This value determines the duration of the tone in ms when when a
"ButtonRelease" event is sent.
Range: "0" - "255"
Default: "10"
- Option
BeamTimeout value
- Determines the time span in seconds, that has to elapse
before a beam is considered defective, blanked-out and excluded from the
coordinates evaluation.
Range: "0" - "65535"
Default: "30" (30 seconds)
- Option TouchTime value
- Determines the minimum time span in steps of
10ms for a valid interruption. In order for an interruption to be reported
to the host computer as valid, it needs to remain at the same spot for
at least the time span declared here.
Range: "0" - "255"
Default: "0" (=6,5
ms)
- Option EnterCount count
- Number of skipped "enter reports". Reports
are sent approx. every 20ms.
Range: "0" - "31"
Default: "3" (3 skipped
messages = 60ms)
- Option ZEnterCount count
- Number of skipped "enter reports"
while in pressure sensitive mode. Reports are sent approx. every 20ms.
Range:
"0" - "31"
Default: "1" (1 skipped messages = 20ms)
- Option LockZEnterTime
count
- Minimum duration of an AreaPressEnter state (Pressure > AreaPressure)
before a PressEnter event is issued. The time is given in 10ms steps.
Range:
"0" - "255"
Default: "1" (10ms)
- Option LockZExitTime count
- Minimum duration
of an AreaPressExit state (Pressure < AreaPressure/2) before a PressExit
event is issued. The time is given in 10ms steps.
Range: "0" - "255"
Default:
"1" (10ms)
- Option LockZLockTime count
- Minimum gap between a PressExit
and a PressEnter event. The time is in 10ms steps.
Range: "0" - "255"
Default:
"10" (100ms)
- Option DualCount count
- Number of skipped "dual touch error".
Reports are sent approx. every 20ms. This option is only available for "ZPress"
and "ZPress Exit" modes.
Range: "0" - "31"
Default: "2" (2 skipped messages
= 40ms)
Xorg(1x)
, xorg.conf(5x)
, xorgconfig(1x)
, Xserver(1x)
,
X(7)
.
2000-2003 - written by Citron GmbH ([email protected])
Table of Contents